This site has limited support for your browser. We recommend switching to Edge, Chrome, Safari, or Firefox.

December Deals: Up to 25% off Still time for Shipping!

Cart 0

No more products available for purchase

Products
Pair with
Subtotal Free
Cart buttons
Shipping, taxes, and discount codes are calculated at checkout

Your Cart is Empty

Timeless Eleven User Guide

Previously named Model Eleven

A. Quick Start

How to Pour with Timeless Eleven

B. Features

C. Important Safety Guidelines

Safety

Click here to view important Safety Guidelines.

D. Installing and Optimizing Capsules

Getting the Most Out of Coravin Pure™ Capsules

On average, each Coravin Pure™ Capsule will enable you to pour about fifteen 5 ounce glasses of wine with Coravin Timeless Systems. To get the most out of each Coravin Pure™ Capsule, we recommend setting your slider to a slower pour speed. If you hear a hissing sound when you stand your bottle up after pouring you are using more Argon gas than is necessary for your pour. Consider decreasing the pour size to ensure better optimization. And, don’t forget, it takes more Argon gas to pour when you get down to the bottom of the bottle, so pull the cork if you know you will be drinking the rest of the bottle that day.

Step-by-Step Guide

1A. Hold Clamp Release Lever Up. 1B. Slide Clamp all the way up.

2. Unscrew Capsule Cup.

3. Insert round end of Capsule into Capsule Cup.

4. Quickly screw Cup back onto System until there is no gap and Cup is aligned. This ensures a tight seal and no gas loss.

5. Slide Clamp down until it locks into place.

Note: A RED Light Ring indicates Coravin Capsule is empty and needs to be replaced. DO NOT replace Coravin Capsule before Light Ring is RED. It will waste all remaining gas.

Note: Coravin Capsules are made of recyclable materials. EMPTY Capsules can be recycled according to local regulations. DO NOT dispose of unused Capsules.

E. Pouring Wine

NOTE: Use on bottles with natural cork (remove foil to confirm), or on screw cap bottles using Coravin Timeless Screw Caps.

NOTE: Make sure Clamp is in the down position before use.

Step-by-Step Guide

1. Pick up System. Light Ring will illuminate BLUE indicating System is ready for use.

2. Place clamp over neck of bottle.

3. Push down with palm of hand on metal surface to insert Needle through cork. Push until Light Ring turns GREEN, indicating System is ready to pour.

4. Hold Spout over glass and tilt bottom of bottle up until wine pours automatically. Light Ring with illuminate GREEN in a cascading motion.

5. Tip bottle upright to stop pouring.

6. Hold bottle with one hand. With other hand, flip up Handle and pull System straight up and off in one swift motion. NOTE: A few drops of residual wine may be seen on top of the cork.

7. Rinse System before storing.

8. Store bottle on its side in temperature controlled area suitable for wine.

F. Changing Between Sip & Glass Modes

Step-by-Step Guide

1. Push Button to toggle between “Sip” and “Glass” Modes.

2a. “Sip” pours about 1-2oz (30-60ml) of wine.

2b. “Glass” pours about 5-6oz (150-180ml) of wine.

G. Charging the System

Step-by-Step Guide

1. Connect the USB cord to any standard USB power adapter, 5V, 2.4A max.

2. Plug USB power adapter into power outlet.

3. Plug smaller end of USB cord into System’s Charger Port. A full charge may take up to two hours. Note: Battery icon will pulse when charging. It will be solid WHITE when fully charged.

4. Disconnect USB cord from System before use.

H. Connecting Your Timeless Eleven to the Moments App

Step-by-Step Guide

1. Download and open the Coravin Moments App from the App Store® for iPhones.

2. Navigate to “My Coravin Systems” from the main menu.

3. Click “Add a System".

4. Select the “Model Eleven”.

5. Select “Add to My Systems.” The System will automatically pair with the iPhone®. NOTE: You will be asked to create an account during this process.

6. The Bluetooth icon on the Model Eleven and iPhone screen will illuminate when connection is complete.

I. Cleaning the System

How to Clean the Timeless Eleven System

Step-by-Step Guide

1. Rinse System before storing by placing Spout under steady stream of warm, clean water for at least 5 seconds.

2. Dry with soft cloth.

J. Clearing the Needle

How to Clear Your Coravin Timeless Eleven Needle

Step-by-Step Guide

1. Flip Handle up and twist quarter turn counter-clockwise. Pull up to remove.

2. Run warm, clean water through Spout.

3. Pull Needle by grip, straight up and out of System.

4. Remove Needle following steps 1-3 from previous section: “Thoroughly Cleaning the System”.

5. Insert Needle Clearing Brush into top of Needle and twist to release particles. Remove Brush. Repeat as needed.

6. Submerge open end of Needle Clearing Tool in cup of warm, clean water. Pull plunger to draw water into Tool.

7. Insert Needle into open end of Tool until fully seated.

8. Press plunger quickly to push water through Needle. (Note: Repeat until Needle is clear.)

9. Reassemble System following steps 6-9 from previous section: “Thoroughly Cleaning the System”.

K. Traveling with the System

Step-by-Step Guide

System uses a Lithium Ion battery and compressed gas. For air travel, be sure to comply with all airline regulations. Many airlines do not allow travel with compressed gas (Coravin Capsules). To conserve battery while in transit, put System into Travel Mode.

1. Press and hold Button until Sip and Glass Icons blink (about 5 seconds).

2. To disable Travel Mode, push Button once. Note: System will not operate in Travel Mode. Disable by pressing Button once when ready to pour wine.

L. Troubleshooting

Wine is not pouring.

Probable Cause: System is not completely seated onto wine bottle (Light Ring is still BLUE).
Solution: Push System completely down further onto bottle. Light Ring will turn GREEN.

Probable Cause: Bottle is not tilted enough.
Solution: Raise bottom of bottle higher. System will pour automatically when bottle is tilted enough.

Probable Cause: Battery is empty.
Solution: Charge System.

Probable Cause: Coravin Capsule is empty or missing. Light Ring is RED.
Solution: Install new Coravin Capsule only when Light Ring is RED.

Probable Cause: Needle is clogged or damaged.
Solution: Replace if damaged. If clogged, refer to “Clearing the Needle”.

Probable Cause: Filter in Needle is clogged.
Solution: Refer to “Cleaning the System” .

Wine is pouring slowly.

Probable Cause: Pour slows down before System is finished pouring glass of wine.
Solution: This is normal. Wine pours more slowly towards end of glass.

Probable Cause: Sip Mode may be engaged. Sip Icon is illuminated.
Solution: Push Button to turn Sip Mode off and pour faster.

Probable Cause: Needle is clogged or damaged.
Solution: Replace if damaged. If clogged, refer to “Clearing the Needle.”

Probable Cause: Filter in Needle is clogged.
Solution: Refer to “Cleaning the System.”

It is difficult to insert and remove System from wine bottles.

Probable Cause: Coating on Needle may be worn.
Solution: Replace Needle if tip is worn or damaged.

Probable Cause: Some corks are more difficult than others.
Solution: This is normal. Use Handle for extra leverage to remove System from bottle.

Probable Cause: Wine is built up on the Clamp.
Solution: Rinse clamp thoroughly under warm, clean water. Refer to “Cleaning the System.”

The cork is leaking/dripping.

Probable Cause: Bottle has a plastic cork which does not reseal.
Solution: Only access wines with natural corks.

Probable Cause: System was left in the cork for too long.
Solution: Remove Coravin System immediately after pouring.

Probable Cause: Wine left in Needle sometimes drips onto the top of cork.
Solution: This is normal even if cork has resealed. Wipe top of the cork with paper towel or cloth.

Probable Cause: Cork might be cold, old, or dry and has difficulty resealing.
Solution: Give the cork additional time to reseal.

There are particles in the wine.

Probable Cause: Cork particles or sediment in the wine have passed through Needle.
Solution: This is normal for some wines.

Coravin Moments App for iPhone does not find System via Bluetooth®.

Probable Cause: Bluetooth is not enabled on the iPhone.
Solution: Enable Bluetooth on iPhone.

Probable Cause: Coravin Moments App is not downloaded on iPhone.
Solution: Download Coravin Moments App to iPhone from App Store.

Probable Cause: System is too far from iPhone.
Solution: Move System closer to iPhone.

Probable Cause: System battery is empty.
Solution: Charge System.

Probable Cause: System is connected to different iPhone.
Solution: Disconnect System from other iPhone. System can only be connected to one device at a time.

System is unresponsive.

Probable Cause: System is in Travel Mode.
Solution: Push Button once to exit Travel Mode.

Probable Cause: Battery is empty.
Solution: Charge System.